Product Overview

The JZSZ-9CD Automatic Potentiometric Titrator is designed in accordance with relevant international standards. It consists of electronic circuitry, a titration system with an imported Metrohm (Switzerland) dosing unit, a stirrer, and a PC. Its compact construction, high level of automation, and accurate analytical results make it suitable for routine use in laboratories, analytical departments, research, and teaching.

The instrument acquires electrode potential values from the reference and measuring electrodes and identifies the titration endpoint, such as the point of maximum potential change or a preset constant potential. It uses the corresponding volume of standard titrant to determine the ion content in the sample, then calculates the analyte concentration from the chemical reaction equation. Applications include acid-base, redox, precipitation, complexometric, and coordination titrations, including acid value analysis when configured with the appropriate method.

Titration curves can be smoothed and endpoint positions corrected to help improve result accuracy.

Key Advantages

High input impedance supports accurate potential measurement.
A 24-bit analog-to-digital converter provides high potential resolution and linearity.
Imported Metrohm dosing unit. Corrosion- and oil-resistant materials are used throughout the dosing assembly to support sealing and smooth operation.
Imported motor drive with a step angle of 0.9° supports accurate and repeatable titrant delivery.
Software automatically screens potential readings and smooths titration curves to help filter false endpoints.
Flexible titration parameter settings can be configured for other applications.
Titration results are automatically saved in a database for later retrieval.
A printer can be connected to print titration curves and results.
Straightforward software interface for easy learning and operation.
Automatic endpoint determination and manual endpoint selection are available. The software can correct endpoint volume when needed, helping produce a result if titration parameters are not ideally set.
Fixed-volume dispensing function.
Automatic cleaning function.
The number of endpoints can be set, supporting separate titration of mixed ions.
Endpoint search modes are selectable: constant potential or inflection point.
Automatic Acid Value Analyzer5

Technical Specifications

ParameterSpecification
Potential measurement range0 to ±2000 mV
Electronic unit basic error0.1% of full-scale reading ±0.001 mV
Minimum titration volume0.001 mL
Input impedanceRi ≥ 1 × 10¹² Ω
Burette volume10 mL; options from 10 to 50 mL
Burette accuracy±0.01% F.S.
Measurement range (pH)0–20
PrecisionConforms to relevant potentiometric titration standards, including GB/T 1792, SH/T 0162, GB/T 264, and ASTM D664
Dimensions (L × W × H)250 × 260 × 350 mm
Main unit weight8 kg

Standard Configuration

No.ItemQuantityNotes
1Main instrument1 unitIncludes imported Metrohm dosing unit
2Computer1 setMay be supplied by the user
3Magnetic stirrer1 unit 
4Serial communication cable1 pc 
5Short-circuit plug1 pc 
6Fuse (1.5 A)2 pcsFor the main unit power inlet
7Reference electrode1 pcCustom-made by the manufacturer
8Measuring electrode1 pcCustom-made by the manufacturer
9Magnetic stir bar1 pc 
10Power cord2 pcs 
11Documentation1 set

On This Page