Product Overview
The Automatic Kinematic Viscometer is designed for testing the kinematic viscosity of liquid petroleum products that behave as Newtonian fluids. It complies with GB/T 265, the test method for kinematic viscosity of petroleum products and calculation of dynamic viscosity. With temperature control accuracy of up to ±0.03°C, it can test up to four glass capillary viscometers simultaneously at the same bath temperature. The instrument can also be used as a high-precision constant-temperature bath.
Working Principle
A measured sample flows by gravity through a calibrated glass capillary viscometer in a temperature-controlled bath. An optical sensor records the time required for the liquid to pass between the upper and lower timing marks. Kinematic viscosity is calculated by multiplying the capillary constant by the flow time. The instrument can automatically calculate, store, and output derived parameters such as viscosity index and dynamic viscosity. An inverted-flow capillary viscometer can be selected for dark oils.
Applicable Standards
GB/T 265-1988, Test Method for Kinematic Viscosity of Petroleum Products and Calculation of Dynamic Viscosity; ASTM D445; ISO 3104; GB/T 10247, General Principles for Viscosity Measurement. Viscosity index calculation: GB/T 1995 and ASTM D2270.
Applications

Model Comparison
| Comparison Item | JZND 9000B Four-Position Manual | JZ-ND265-1B Two-Position Fully Automatic | JZ-ND265S-2B Four-Position Fully Automatic |
| Test positions | 4 | 2 | 4 |
| Automation level | Temperature control; manual sample loading and timing | Fully automatic sample loading and drying | Fully automatic sample loading and drying |
| Temperature range | Room temperature to 149°C | Room temperature to 100°C | Room temperature to 100°C |
| Temperature control accuracy | ±0.03°C | ±0.01°C | ±0.01°C |
| Sensor | Platinum resistance thermometer | PT100 | PT1000 |
| Key functions | Stores 1,000 results; panel stopwatch timing | Viscosity index calculation; wireless remote control supplied as standard | Dynamic, intrinsic, relative viscosity and specific viscosity; USB interface |
| Data storage | 1,000 records | 200 records | 100 records |
| Over-temperature protection | — | Power cut-off protection at 100°C | Power cut-off protection at 105°C |
| Power supply and rating | AC 220 V, 1,300 W | AC 220 V, 1,200 W | AC 220 V, 1,200 W |
| Optional configuration | — | Can be configured with a chilled water circulation bath for low-temperature testing | Can be configured with a chilled water circulation bath for low-temperature testing |
| Recommended use | Budget-conscious routine laboratory testing with manual operation | Moderate sample throughput; fully automatic operation in a compact footprint | High sample throughput and parallel fully automatic testing |